Electrode Fill Solutions Code Description Package HI7071 3.5M KCl with AgCl reference electrolyte 30 mL bottle (4) HI7071M 3.5M KCl with AgCl reference electrolyte 250 mL bottle HI7071L 3.5M KCl with AgCl reference electrolyte 500 mL bottle HI7072 1M potassium nitrate electrode fill solution 30 mL bottle (4) HI7072L 1M potassium nitrate electrode fill solution 500 mL bottle HI7075 1.7M potassium nitrate, 0.7M potassium chloride electrode fill solution 30 mL bottle (4) HI7076 1M sodium chloride electrode fill solution 30 mL bottle (4) HI7078 0.5M ammonium sulfate electrode fill solution 30 mL bottle (4) HI7082 3.5M KCl reference electrolyte fill solution 30 mL bottle (4) HI7082M 3.5M KCl reference electrolyte fill solution 250 mL bottle HI7082L 3.5M KCl reference electrolyte fill solution 500 mL bottle HI8071 3.5M KCl with AgCl reference electrolyte 30 mL FDA bottle (4) HI8082 3.5M KCl reference electrolyte fill solution 30 mL FDA bottle (4) HI8093 1M KCl with AgCl reference electrolyte 30 mL FDA bottle (4) HI9071 gelled bridge electrolyte for FC2053 pH electrode and HI981030 GroLine® pH tester 13 mL bottle HI7094 1M LiCl in ethanol electrode filling solution for non-aqueous titration. For use with HI1151B, HI1049B, and HI3149B probes. The use of the LiCl in ethanol filling solution helps to ensure accurate measurements in the non-aqueous solvent environment during the titration process. This non-aqueous titration method is a reliable and widely accepted technique for determining the total fatty acid content in various types of oils, including olive oil. Before use, it is necessary to remove the original filling solution, rinse and fill with HI7094S (alcoholic solution). After the titration, remove the latter solution and fill again with HI7082 solution. 30 mL bottle (4) Accessories Code Description HI740155P Capillary Pipette for Electrode refilling (20 pcs) Electrode Fill Solutions • Expiration date · The production batch number and expiration date are reported on all Hanna calibration solutions. • Air-tight bottles · Air-tight bottle with tamper-proof seal of freshness to ensure quality. • FDA compliant bottles (HI80xx) · Hanna solutions are offered in opaque bottles that meet FDA requirements. The electrolyte level in re›llable electrodes should be checked before performing any measurements. If the level is low, re›ll with the proper electrolyte solution to ensure optimum performance. This simple maintenance helps guarantee adequate head pressure to promote the °ow of reference electrolyte into the sample being measured. 2 pH 2.180 | www.hannainst.com solutions

RkJQdWJsaXNoZXIy MTI3NTM=