HANNA® instruments Catálogo General v38

Specifications HI84534 Titrator Range 0.3 to 10.0 % w/v (g/100mL) as acetic acid 3 to 100 g/L as acetic acid Resolution 0.1%, 1g/L Accuracy (@25°C/77°F) 3% of reading or ± 0.1 % , whichever is greater 3% of reading or ± 1 g/L, whichever is greater Sample Volume 1 mL Titration Method Acid-base titration Principle Fixed end point titration to pH 8.2 Pump Speed 10 mL/min Stirring Speed 600 rpm Data storage up to 200 titrations pH/mV Meter pH Range -2.0 to 16.0 pH / -2.00 to 16.00 pH pH Resolution 0.1 pH / 0.01 pH pH Accuracy (@25°C/77°F) ± 0.01 pH pH Calibration one, two or three-point calibration; four available buffers (pH 4.01, 7.01, 8.20, 10.01) mV Range -2000.0 to 2000.0 mV mV Resolution 0.1 mV mV Accuracy (@25°C/77°F) ± 1.0 mV Data storage up to 200 data points (pH or mV) Temperature Range -20.0 to 120.0°C; -4.0 to 248.0°F Resolution 0.1°C; 0.1°F Accuracy (@25°C/77°F) ±0.4°C; ±0.8°F without probe error Compensation manual or automatic Additional Specifications pH Electrode HI1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included) Temperature Probe HI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included) Connectivity (1) Type-B USB for PC interface, (1) Type-A USB for storage Environment 0 to 50°C (32 to 122 °F); max 95% RH non-condensing Power Supply 12 VDC power adapter Dimensions 235 x 200 x 150 mm (9.2 x 7.9 x 5.9”) Weight 1.9 kg (67.0 oz.) Ordering Information HI84534-01 (115V) and HI84534-02 (230V) are supplied with HI1131B pH electrode, HI7662-T temperature probe, HI7082 electrode fill solution, HI84534-70 reagent kit for water analysis, 100 mL beakers (2), dosing pump valve, 5 mL syringe, 1 mL plastic pipette, tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), stir bar, power adapter, instruction manual and quality certificate. On-screen Features pH meter with electrode condition on display The HI84534 also functions as a pH meter. The HI84534 also displays the electrode condition on the LCD using Hanna’s exclusive electrode diagnostics. Easy and clear measurement The HI84534 is a single parameter titrator designed to measure acidity in a few easy steps. The HI84534 displays the results directly on the screen in user-selectable units. Titration curve displayed on screen The HI84534 offers real time graphing of the titration curve on the LCD. See reagents and accessories on page 4.78 4 Titration 4.57 www.hannainst.com |

RkJQdWJsaXNoZXIy MTI3NTM=