Application-specific ORP Electrode The HI84500 is supplied with the HI3148B ORP electrode featuring CPS™ technology to prevent the clogging of the reference junction. Conventional electrodes may clog quickly in biological samples such as wine. By design, the HI3148B ORP electrode utilizes a ground glass/PTFE sleeve junction which controls a steady, predictable flow of electrolyte solution, keeping the junction open. The hydrophobic properties of PTFE repels wetness and coatings. Specifications HI84500 Titrator Range Low Range: 1.0 to 40.0 ppm of SO₂ High Range: 30 to 400 ppm of SO₂ Resolution Low Range: 0.1 ppm High Range: 1 ppm Accuracy (@25°C/77°F) Low Range: ±0.5 ppm or 3% of reading, whichever is greater High Range: ±1 ppm or 3% of reading, whichever is greater Sample Volume 50 mL Method Ripper method Principle equivalence point redox titration Pump speed 10 mL/min Stirring Speed 700 rpm ORP Meter Range -2000.0 to 2000.0 mV Resolution 0.1 mV Accuracy (@25°C/77°F) ±1 mV Additional Specifications Logging Data up to 400 samples (200 ORP/mV, 200 titration) Electrode HI3148B glass body ORP electrode with BNC connector and 1 m (3.3’) cable (included) Connectivity (1) Type-B USB for PC interface, (1) Type-A USB for storage Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing Power Supply 12 VDC adapter (included) Dimensions 235 x 200 x 150 mm (9.2 x 7.9 x 5.9”) Weight 1.9 kg (67.0 oz.) Ordering Information HI84500-01 (115V) and HI84500-02 (230V) are supplied with HI3148B ORP electrode, HI7082 electrode fill solution (30 mL), HI8450070 reagent kit for SO₂ determination (consisting of: 1 bottle HI84500-50 (230 mL) low range titrant, 1 bottle HI84500-51 high range titrant (230mL), 1 bottle HI84500-55 pump calibration standard (120 mL), 1 bottle HI84500-60 acid reagent (230 mL), 1 bottle HI84500-61 alkaline reagent (120 mL) and HI84500-62 stabilizer packets (100 packets)), 100 mL beakers (2), 20 mL beakers (2), scissors, dosing pump valve, 5 mL syringe, 1 mL plastic pipette, tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), stir bar, electrode cleaning solution sachets for wine deposits (2), electrode cleaning solution sachets for wine stains (2), power adapter, instruction manual and quality certificate. On-screen Features Tutorial and help screens Accessing the tutorial menu provides helpful information during calibration and titration. GLP Records pump calibration data to ensure measurements are accurate and reliable. Titration curve displayed on screen The HI84500 offers real time graphing of the titration curve on the LCD. Log and recall data Log up to 400 samples (200 for titration results; 200 for ORP/mV) and recall or export data to a USB stick or PC. ORP During ORP measurements, the stirrer icon will be displayed when the stirrer is on Procedure warnings Users are warned if there is an error in procedures such as the titration exceeded the maximum volume of titrant. See reagents and accessories on page 4.80 4 Titration 4.69 www.hannainst.com |

RkJQdWJsaXNoZXIy MTI3NTM=