HANNA® instruments Catálogo General v39

Specifications HI6321 Conductivity Range 0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm Resolution 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm Accuracy ±1 % of reading (±0.01 μS/cm) Cell Constant 0.0500 to 200.0000 /cm Calibration Type Automatic; Manual Calibration Points Single; Multiple Calibration Solutions 84.00 μS/cm; 1.413 mS/cm; 5.000 mS/cm; 12.88 mS/cm; 80.00 mS/cm; 111.8 mS/cm Calibration Reminder Disabled Daily: 0 min. to 23 hours and 59 min. Periodic: 1 min. to 30 days, 23 hours and 59 min. Temperature Compensation Linear; Natural; Standard; Disabled Reference Temperature Range 5.0 to 30.0 °C (41.0 to 86.0 °F) Resolution 0.1 °C / 0.1 °F Temperature Coefficient 0.00 to 10.00 %/°C Resistivity Range 1.0 to 99.9 Ω·cm; 100 to 999 Ω·cm; 1.00 to 9.99 KΩ·cm; 10.0 to 99.9 KΩ·cm; 100 to 999 KΩ·cm; 1.00 to 9.99 MΩ·cm; 10.0 to 100.0 MΩ·cm Resolution 0.1 Ω·cm; 1 Ω·cm; 0.01 KΩ·cm; 0.1 KΩ·cm; 1 KΩ·cm; 0.01 MΩ·cm; 0.1 MΩ·cm Accuracy ±1 % of reading (±1 Ω·cm) Total Dissolved Solids (TDS) Range 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor) Resolution 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt Accuracy ±1 % of reading (±0.01 ppm) Salinity Range 0.00 to 42.00 PSU - Practical Scale 0.00 to 80.00 ppt - Natural Sea Water 0.0 to 400.0 % - Percent Scale Resolution 0.01 for Practical Scale / Natural Sea Water 0.1 % for Percent Scale Accuracy ±1 % of reading Calibration 1 point for percent scale, using 100 % salinity calibration solution Temperature Range −20.0 to 120.0 °C −4.0 to 248.0 °F 253.0 to 393.0 K Resolution 0.1 °C; 0.1 °F; 0.1 K Accuracy ±0.2 °C; ±0.4 °F; ±0.2 K Calilbration Single point, adjustable Reading Modes Direct Direct/Autohold Stability criteria Accurate Medium Fast Views Basic Conductivity, Resistivity, TDS, Salinity, Temperature measurement data Measurement profile (if enabled) Stability stats Simple GLP Basic view information Last calibration date, offset Full GLP Conductivity & Salinity Simple GLP information and calibration point details C ell constant, reference and source temperature Graph (Plot) Measurement versus time graph (panned or zoomed) Table Measurements updated every second (displayed in table) Logging Type Automatic, Manual, Autohold Number of records 50 000 maximum per file Stores at least 1 000 000 data points per user Automatic interval 1, 2, 5, 10, 30 seconds 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes Sample ID Incremental mode or manual Export option .CSV file format Users Up to 9 users and the default administrator account Connectivity USB-A 2 ports for keyboard input, USB thumb drive, and USB printer USB-C 1 port for PC connectivity and USB-C type thumb drive Wi-Fi & Ethernet FTP Web server Log transfer and download Email RS232 Connecting peripherals Power supply DC adapter 100-240 VAC to 24 VDC 2 A Environment 0 - 50 °C / 32 - 122 °F / 273 - 323 K maximum 95% RH non-condensing Dimensions 205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “) Weight Approximately 1.2 kg (26.5 lbs.) Ordering Information HI6321 is supplied with HI7631233 EC and resistivity probe; HI764060 electrode holder with following accessories: base plate (with integrated pivot pin) and screw (requires installation), cable holder clip, attached, electrode holder with adapter (attached); EC calibration starter kit consisting of: 1413 μS/cm standard solution (4 sachets), 12880 μS/cm standard solution (2 sachets), 5000 μS/cm standard solution (2 sachets); electrode rinse solution (2 sachets); 24 VDC power adapter; USB-C to USB-A cable; probe quality certificate; quick reference guide; instrument quality certificate. EC, TDS and Salinity solutions begin on page 5.34; see HI6000180 magnetic stirrer on page 8.8 5 Conductivity / TDS 5.15 www.hannainst.com | benchtop

RkJQdWJsaXNoZXIy MTI3NTM=