Specifications HI98192 EC Range 0 to 400 mS/cm (shows values up to 1000 mS/cm actual conductivity)** 0.001 to 9.999 µS/cm*; 10.00 to 99.99 µS/cm; 100.0 to 999.9 µS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (autoranging) Resolution 0.001 µS/cm*; 0.01 µS/cm; 0.1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm Accuracy ±1% of reading (±0.01 µS/cm or 1 digit, whichever is greater) Calibration automatic up to five points with seven memorized standards (0.00 µS/cm, 84.0 µS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) TDS Range 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 g/L; 10.00 to 99.99 g/L; 100.0 to 400.0 g/L (autoranging) Resolution 0.01 ppm; 0.1 ppm; 0.001 g/L; 0.01 g/L; 0.1 g/L Accuracy ±1% of reading (±0.05 ppm or 1 digit, whichever is greater) Resistivity Range 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm* (autoranging) Resolution 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm* Accuracy ±1% of reading (±10 Ω or 1 digit, whichever is greater) Salinity Range % NaCl : 0.0 to 400.0%; practical salinity: 0.00 to 42.00 (PSU); seawater scale: 0.00 to 80.00 (ppt) Resolution 0.1%; 0.01 Accuracy ±1% of reading Calibration max. one point only in % NaCl range with HI7037 standard; use conductivity calibration for all other ranges Temperature † Range -20.0 to 120.0°C; -4.0 to 248.0°F Resolution 0.1°C; 0.1°F Accuracy ±0.2°C; ±0.4°F (excluding probe error) Calibration one or two points Additional Specifications Cell Constant Setup 0.010 to 10.000 Temperature Compensation NoTC, linear (-20.0 to 120.0°C (-4.0 to 248.0°F)), non linear (0 to 36°C (32 to 98.6°F)) ISO/DIS 7888 std Reference Temperature 15°C, 20°C and 25°C Temperature Coefficient 0.00 to 10.00 %/°C TDS Factor 0.40 to 1.00 Probe HI763133 stainless steel, four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9’) cable (included) Logging log-on-demand: 400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Memorized Profiles up to 10 Measurement Modes autorange, autoend, lock and fixed range PC Connectivity opto-isolated sealed USB (with HI92000 software and micro USB cable) Battery Type / Life 1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight; Auto-off user selectable: 5, 10, 30, 60 min, disabled Environment 0 to 50°C (32 to 122°F); RH 100% IP67 Dimensions/Weight 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) / 400 g (14.2 oz.) Ordering Information HI98192 is supplied with HI763133 stainless steel, four-ring conductivity/TDS probe, HI7031M 1413 µS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), quick start guide, quality certificate and instruction manual in an HI720192 rugged carrying case with custom insert. Accessories HI710034 orange protective rubber boot * The 0.001 μS/cm EC range and 0.1 MΩ•cm Resistivity range are not available with the 1.5 m cable probe **Uncompensated temperature reading (†) Reduced to actual sensor limits EC, TDS and Salinity solutions begin on page 5.34 Rugged custom carrying case The HI98192 meter, probe, and all accessories are supplied in the HI720192 rugged carrying case designed to provide years of use. The inside compartment of the carrying case is thermoformed to securely hold and protect all of the components. 5 Conductivity / TDS 5.26 | www.hannainst.com portable

RkJQdWJsaXNoZXIy MTI3NTM=