Specifications HI98197 EC Range 0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual conductivity*; temperature compensated to 400 mS/cm) Resolution 0.001 µS/cm; 0.01 µS/cm; 0.1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm Accuracy ±1% of reading (±0.01 µS/cm or 1 digit, whichever is greater) Calibration automatic up to five points with seven memorized standards (0.00 µS/cm, 84.0 µS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) TDS Range 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 g/L; 10.00 to 99.99 g/L; 100.0 to 400.0 g/L (autoranging) Resolution 0.01 ppm; 0.1 ppm; 0.001 g/L; 0.01 g/L; 0.1 g/L Accuracy ±1% of reading (±0.05 ppm or 1 digit, whichever is greater) Resistivity Range 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm (autoranging) Resolution 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm Accuracy ±1% of reading (±10 Ω or 1 digit, whichever is greater) Salinity Range % NaCl : 0.0 to 400.0%; practical salinity: 0.00 to 42.00 (PSU); seawater scale: 0.00 to 80.00 (ppt) Resolution 0.1%; 0.01 Accuracy ±1% of reading Calibration max. one point only in % NaCl range with HI7037 standard; use conductivity calibration for all other ranges Temperature † Range -20.0 to 120.0°C; -4.0 to 248.0°F Resolution 0.1°C; 0.1°F Accuracy ±0.2°C; ±0.4°F (excluding probe error) Calibration one or two points Additional Specifications Cell Constant Setup 0.010 to 10.000 Temperature Compensation NoTC, linear (-20.0 to 120.0°C; -4.0 to 248.0°F), non linear (0 to 36°C; 32 to 98.6°F) ISO/DIS 7888 std Reference Temperature 15°C, 20°C, and 25°C Temperature Coefficient 0.00 to 10.00 %/°C TDS Factor 0.40 to 1.00 Probe HI763123 platinum, four-ring conductivity/TDS probe with internal temperature sensor and 1 m (3.3’) cable (included) Logging log-on-demand: 400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Memorized Profiles up to 10 Measurement Modes autorange, autoend, lock, and fixed range PC Connectivity opto-isolated sealed USB (with HI92000 software and micro USB cable) Battery Type / Life 1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight Auto-off user selectable: 5, 10, 30, 60 min, disabled Environment 0 to 50°C (32 to 122°F); RH 100% IP67 Dimensions/Weight 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) / 400 g (14.2 oz.) Ordering Information HI98197 is supplied with HI763123 platinum, four-ring conductivity/TDS probe with internal temperature sensor and 1 m (3.3’) cable, HI605453 stainless steel flow cell for ultrapure water, tubing, HI7031M 1413 µS/cm calibration solution (230 mL), HI7033M 84 µS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V batteries (4), quality certificate, instruction manual and quick start guide in an HI720197 rugged carrying case with custom insert. Accessories HI710034 orange protective rubber boot Supplied complete HI98197 is supplied complete with sensor, ow cell, tubing, calibration solution, beakers, PC software and connection cable, instruction manual, quick start guide and batteries in the HI720197 rugged, custom carrying case. *Uncompensated temperature reading (†) Reduced to actual sensor limits EC, TDS and Salinity solutions begin on page 5.34 5 Conductivity / TDS 5.30 | www.hannainst.com portable
RkJQdWJsaXNoZXIy MTI3NTM=