Measurement • Measure pH or mV with temperature (HI6000-1); Measure pH, mV, or ISE with temperature (HI6000-2) • Application-specific profiles allow quick and direct measurement without the need to update the sensor and system settings • Active log during measurement • Measurement stability indicator (using the Stability Criteria setting) • Reading modes: · Direct and direct/autohold · Known Addition, Known Subtraction, Analyte Addiiton, Analyte Subtration (HI6000-2) • Temperature compensation can be Automatic (using temperature probe) or set manually • Audible and/or alarm messages for measurements outside of predefined limits • Galvanic isolation for pH/ORP measurement Calibration • pH calibration using · Up to five Hanna Instruments pH buffers (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45) · Up to five custom buffers • mV calibration for ORP using a single point to calibrate offset. • ISE calibration using up to five nominal standard values (e.g. for ppm: 0.010, 0.100, 1.00, 10.0, 100, 1000, 10000 ppm) and/or up to five custom solutions (user supplied) * The range may be limited by the probe’s limits. Specifications HI6000 with HI6000-1 pH/ORP Module HI6000 with HI6000-2 pH/ORP/ISE Module pH Range* -2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH Resolution 0.1 pH; 0.01 pH; 0.001 pH Accuracy ±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit) Temperature compensation Automatic or manual Calibration points up to 5 Type Automatic; Semiautomatic; Manual Standard buffers Hanna and NIST pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 Custom buffers Up to 5 Custom group Up to 5 1st calibration point Offset or point (user setting) Isopotential point −2.000 to 20.000 pH mV Range −2000.0 mV to 2000.0 mV Resolution 1 mV; 0.1 mV Accuracy ±0.2 mV ±1 last significant digit Calibration Single point offset, ±2000.0 mV ISE (HI6000-2 module only) Range — 1.0×10¸¹ to 300.0 ppt (g/L or mg/mL) 5.0×10¸º to 1.0×105 ppm (mg/L or µg/mL) 1.0 to 5.0×107 ppb (µg/L) 1.0×10¸¼ to 10.0 M (mol/L) 1.0×10¸½ to 1.0×104 mmol/L 1.0×10¸¾ to 60.0 %w/v 5.0×10¸¼ to 5.0×107 user Resolution — 1, 2, 3 significant digits Accuracy — ±0.5% (monovalent ions) ±1% (divalent ions) Calibration points — Up to 5 Calibration type — All standards Standard group Standards — 7 standard solutions available for each concentration unit Custom standards — Up to 5 Custom group — Up to 5 Temperature Range* -20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.2 to 393.2 K Resolution 0.1 °C; 0.1 °F ; 0.1 K Accuracy ±0.2 °C; ±0.4 °F; ±0.2 Calibration Single point, adjustable Reading mode Direct; Direct/Autohold ISE only: Known Addition, Known Subtraction Analyte Addition, Analyte Subtraction View Basic Measurement data Measurement profile (if enabled) Stability status Simple GLP Basic view information Last calibration date, slope, offset (pH, Rel. mV - ISE only) Full GLP Simple GLP information Calibration point details (pH & ISE) Graph Basic view information Measurement versus time graph Table Basic view information Table with measurements updated every second 7 Multiparameter 7.15 www.hannainst.com | benchtop
RkJQdWJsaXNoZXIy MTI3NTM=