Measurement • Measure μS/cm, mS/cm (Conductivity); Ω·cm, kΩ·cm, MΩ·cm (Resistivity); ppm, ppt (TDS); ppt, PSU, % (Salinity) with temperature • User-specific profiles allow quick and direct measurement without the need to update the sensor and system settings • Active log during measurement • Measurement stability indicator (using the Stability Criteria setting) • Reading modes: direct and direct/autohold • Temperature compensation can be Automatic or set manually • Audible and/or alarm messages for measurements outside of predefined limits • Galvanic isolation for conductivity measurement Calibration • Conductivity calibration using: · Up to four Hanna Instruments standards – 84 μS/cm, 1413 μS/ cm, 5000 μS/cm, 12880 μS/cm, 80000 μS/cm and 111800 μS/ cm – for cell factor determination; and 0 μS/cm for Offset · Up to four custom standards • Salinity (%) calibration using 100% salinity standard * The range may be limited by the probe’s limits. Specifications HI6000 with HI6000-3 EC Module Conductivity Range* 0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm Resolution 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm Accuracy ±1 % of reading or ±0.010 μS/cm, whichever is greater Cell Constant 0.0500 to 200.0000 /cm Calibration Type Automatic manual Calibration Points Single Up to 5 Calibration Solutions 84 μS/cm; 1413 μS/cm; 5000 μS/cm; 12880 μS/cm; 80000 μS/cm; 111800 μS/cm Temperature Compensation Linear; Natural; Standard; Disabled Reference Temperature 5.0 to 30.0 °C (41.0 to 86.0 °F , 278.2 to 303.2 K) Temperature Coefficient 0.00 to 10.00 %/°C Resistivity Range 1.0 to 99.9 Ω·cm; 100 to 999 Ω·cm; 1.00 to 9.99 KΩ·cm; 10.0 to 99.9 KΩ·cm; 100 to 999 KΩ·cm; 1.00 to 9.99 MΩ·cm; 10.0 to 100.0 MΩ·cm Resolution 0.1 Ω·cm; 1 Ω·cm; 0.01 KΩ·cm; 0.1 KΩ·cm; 1 KΩ·cm; 0.01 MΩ·cm; 0.1 MΩ·cm Accuracy ±1 % of reading or ±1 Ω•cm, whichever is greater Total Dissolved Solids (TDS) Range 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor) Resolution 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt Accuracy ±1 % of reading or ±0.01 ppm, whichever is greater Seawater salinity Range 0.00 to 42.00 PSU (Practical Salinity Scale) 0.00 to 80.00 ppt (Natural Sea Water) 0.0 to 400.0 % (Percent Scale) Resolution 0.01 PSU; 0.01 ppt; 0.1 % Accuracy ±1 % of reading Calibration 1 point, using 100 % salinity calibration solution (% scale only) Temperature Range* −20.0 to 120.0 °C; −4.0 to 248.0 °F; 253.2 to 393.2 K Resolution 0.1 °C, 0.1 °F, 0.1 K Accuracy ±0.2 °C, ±0.4 °F, ±0.2 K Calilbration Single point, adjustable Reading mode Direct Direct/Autohold Direct/USP (Conductivity only) View Basic Measurement data Measurement profile (if enabled) Stability status Simple GLP Basic view information Last calibration date and offset Full GLP Simple GLP information Calibration point details (conductivity & salinity) Graph Basic view information Measurement versus time graph Table Basic view information Table with measurements updated every second 7 Multiparameter 7.17 www.hannainst.com | benchtop
RkJQdWJsaXNoZXIy MTI3NTM=