Parameter Range Resolution Accuracy Wavelength Cuvette Type Method Method ID Reagent Code Alkalinity 0 to 500 mg/L (as CaCO²) 1 mg/L ±5 mg/L ±5% of reading at 25 °C 610 nm 22 mm diameter Bromocresol Green #001 HI775-26 Reagents for 25 tests Alkalinity, Marine 0 to 300 mg/L (as CaCO²) 1 mg/L ±5 mg/L ±5% of reading at 25 °C 610 nm 22 mm diameter Bromocresol Green #002 HI755-26 Reagents for 25 tests Aluminum 0.00 to 1.00 mg/L (as Al·+) 0.01 mg/L ±0.04 mg/L ±4% of reading at 25 °C 530 nm 22 mm diameter Adaptation of the Aluminon Method #003 HI93712-01 Reagents for 100 tests HI93712-03 Reagents for 300 tests Ammonia Low Range 0.00 to 3.00 mg/L (as NH²-N) 0.01 mg/L ±0.04 mg/L ±4% of reading at 25 °C 425 nm 16 mm diameter Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler Method #004 HI93700-01 Reagents for 100 tests HI93700-03 Reagents for 300 tests Ammonia Low Range (13 mm Vial) 0.00 to 3.00 mg/L (as NH²-N) 0.01 mg/L ±0.10 mg/L or ± 5% of reading at 25 °C, whichever is greater 425 nm 13 mm diameter Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler Method #005 HI93764A-25 Reagents for 25 tests Ammonia Low Range ISO (13 mm Vial) 0.000 to 2.500 mg/L (as NH¹+) 0.001 mg/L ±0.015 mg/L ± 3% of reading at 25 °C 690 nm 13 mm diameter ISO 23695 #101 HI96791-25 Reagents for 25 tests Ammonia Medium Range 0.00 to 10.00 mg/L (as NH²-N) 0.01 mg/L ±0.05 mg/L ± 5% of reading at 25 °C, whichever is greater 425 nm 16 mm diameter Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler Method #006 HI93715-01 Reagents for 100 tests HI93715-03 Reagents for 300 tests Ammonia High Range 0.0 to 100.0 mg/L (as NH¹+) 0.1 mg/L ±0.5 mg/L ± 5% of reading at 25 °C 425 nm 16 mm diameter Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler Method #007 HI93733-01 Reagents for 100 tests HI93733-03 Reagents for 300 tests Ammonia High Range (13 mm Vial) 0.0 to 100.0 mg/L (as NH²-N) 0.1 mg/L ±1.0 mg/L or ± 5% of reading at 25 °C, whichever is greater 430 nm 13 mm diameter Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler Method #008 HI93764B-25 Reagents for 25 tests Bromine 0.00 to 10.00 mg/L (as Brº) 0.01 mg/L ±0.08 mg/L ±3% of reading at 25 °C 525 nm 22 mm diameter Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, DPD Method #009 HI93716-01 Reagents for 100 tests HI93716-03 Reagents for 300 tests Calcium 0 to 400 mg/L (as Ca»+) 1 mg/L ±10 mg/L ±5% of reading at 25 °C 466 nm 22 mm diameter Adaptation of the Oxalate Method #010 HI937521-01 Reagents for 50 tests HI937521-03 Reagents for 150 tests Calcium, Marine 200 to 600 mg/L (as Ca»+) 1 mg/L ± 5% of reading at 25 °C 610 nm 16 mm diameter Adaptation of the Zincon Method #011 HI758-26 Reagents for 25 tests Chloride 0.0 to 20.0 mg/L (as Cl - ) 0.1 mg/L ±0.5 mg/L ±5% of reading at 25 °C 455 nm 22 mm diameter Adaptation of the Mercury (II) Thiocyanate Method #012 HI93753-01 Reagents for 100 tests HI93753-03 Reagents for 300 tests Chlorine Dioxide 0.00 to 2.00 mg/L (as ClOº) 0.01 mg/L ±0.10 mg/L ±5% of reading at 25 °C 575 nm 22 mm diameter Adaptation of the Chlorophenol Red Method #013 HI93738-01 Reagents for 100 tests HI93738-03 Reagents for 300 tests Chlorine Dioxide (Rapid) 0.00 to 2.00 mg/L (as ClOº) 0.01 mg/L ±0.10 mg/L ±5% of reading at 25 °C 525 nm 22 mm diameter Adaptation of Standard Methods for the Examination of Water and Wastewater, 18th Edition, 4500 ClOº D #086 HI96779-01 Reagents for 100 tests HI96779-03 Reagents for 300 tests Chlorine, Free Ultra Low Range 0.000 to 0.500 mg/L (as Clº) 0.001 mg/L ±0.020 mg/L ±3% of reading at 25 °C 525 nm 22 mm diameter Adaptation of the EPA DPD Method 330.5 #014 HI95762-01 Reagents for 100 tests HI95762-03 Reagents for 300 tests 10 Photometers 10.14 | www.hannainst.com iris® Spectrophotometer
RkJQdWJsaXNoZXIy MTI3NTM=