HANNA® instruments Catálogo General v39

Parameter Range Resolution Accuracy Wavelength Cuvette Type Method Method ID Reagent Code Chemical Oxygen Demand Medium Range Mercury Free (13 mm Vial) 0 to 1500 mg/L (as Oº) 1 mg/L ±15 mg/L or ±3% of reading at 25 °C, whichever is greater 610 nm 13 mm diameter Dichromate Mercury Free #029 HI93754E-25 Reagents for 25 tests Chemical Oxygen Demand Medium Range ISO (13 mm Vial) 0 to 1000 mg/L (as Oº) 1 mg/L ±15 mg/L or ±3% of reading at 25 °C, whichever is greater 610 nm 13 mm diameter Dichromate ISO #030 HI93754G-25 Reagents for 25 tests Chemical Oxygen Demand High Range EPA (13 mm Vial) 0 to 15000 mg/L (as Oº) 1 mg/L ±150 mg/L or ±2% of reading at 25 °C, whichever is greater 610 nm 13 mm diameter Adaptation of the EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters #031 HI93754C-25 Reagents for 25 tests Chemical Oxygen Demand Ultra High Range (13 mm Vial) 0.0 to 60.0 ppt (as Oº) 0.1 ppt ±0.5 ppt ±3% of reading @ 25°C 610 nm 13 mm diameter Adaptation of the EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters #088 HI93754J-25 Reagents for 25 tests Color ADMI Low Range 0 to 250 ADMI Pt-Co 1 ADMI Pt-Co ±5 ADMI Pt-Co at 25 °C 400-700 nm 50 mm diameter ADMI weighted ordinate Method, analogous APHA 2120F Method #099 — Color ADMI High Range 0 to 600 ADMI Pt-Co 1 ADMI Pt-Co ±20 ADMI Pt-Co at 25 °C 400-700 nm 10 mm diameter ADMI weighted ordinate Method, analogous APHA 2120F Method #100 — Color of Water 0 to 500 PCU (Platinum Cobalt Units) 1 PCU ±10 PCU ±5% of reading at 25 °C 460 nm 22 mm diameter Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Colorimetric Platinum Cobalt Method #032 — Copper Low Range 0 to 1500 μg/L (as Cu) 1 μg/L ±10 μg/L ±5% of reading at 25 °C 575 nm 22 mm diameter Adaptation of the EPA Method #033 HI95747-01 Reagents for 100 tests HI95747-03 Reagents for 300 tests Copper High Range 0.00 to 5.00 mg/L (as Cu) 0.01 mg/L ±0.02 mg/L ±4% of reading at 25 °C 560 nm 22 mm diameter Adaptation of the EPA Method #034 HI93702-01 Reagents for 100 tests HI93702-03 Reagents for 300 tests Cyanide 0.000 to 0.200 mg/L (as CN - ) 0.001 mg/L ±0.005 mg/L ±3% of reading at 25 °C 610 nm 22 mm diameter Pyridine-Pyrazalone #035 HI93714-01 Reagents for 100 tests HI93714-03 Reagents for 300 tests Cyanuric Acid 0 to100 mg/L (as CYA) 1 mg/L ±1 mg/L ±15% of reading at 25 °C 525 nm 22 mm diameter Adaptation of the Turbidimetric Method #036 HI93722-01 Reagents for 100 tests HI93722-03 Reagents for 300 tests Fluoride Low Range 0.00 to 2.00 mg/L (as F - ) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 575 nm 22 mm diameter Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, SPADNS Method #037 HI93729-01 Reagents for 100 tests HI93729-03 Reagents for 300 tests Fluoride High Range 0.0 to 20.0 mg/L (as F - ) 0.1 mg/L ±0.5 mg/L ±3% of reading at 25 °C 575 nm 22 mm diameter Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, SPADNS Method #038 HI93739-01 Reagents for 100 tests HI93739-03 Reagents for 300 tests Hardness, Calcium 0.00 to 2.70 mg/L (as CaCO²) 0.01 mg/L ±0.08 mg/L ±4% of reading at 25 °C 523 nm 22 mm diameter Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Calmagite Method #039 HI93720-01 Reagents for 100 tests HI93720-03 Reagents for 300 tests Hardness, Magnesium 0.00 to 2.00 mg/L (as CaCO²) 0.01 mg/L ±0.11 mg/L ±5% of reading at 25 °C 523 nm 22 mm diameter Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, EDTA Colorimetric Method #040 HI93719-01 Reagents for 100 tests HI93719-03 Reagents for 300 tests 10 Photometers 10.16 | www.hannainst.com iris® Spectrophotometer

RkJQdWJsaXNoZXIy MTI3NTM=