HANNA® instruments Catálogo General v39

Parameter Range Resolution Accuracy Wavelength Cuvette Type Method Method ID Reagent Code Hardness, Total Low Range 0 to 250 mg/L (as CaCO²) 1 mg/L ±5 mg/L ±4% of reading at 25 °C 466 nm 22 mm diameter Adaptation of the EPA Method 130.1 #041 HI93735-00 Reagents for 100 tests (LR) HI93735-0 Reagents for 300 tests (LR - 100 tests, MR - 100 tests, HR - 100 tests) Hardness, Total Medium Range 200 to 500 mg/L (as CaCO²) 1 mg/L ±7 mg/L ±3% of reading at 25 °C 466 nm 22 mm diameter Adaptation of the EPA Method 130.1 #042 HI93735-01 Reagents for 100 tests (MR) HI93735-0 Reagents for 300 tests (LR - 100 tests, MR - 100 tests, HR - 100 tests) Hardness, Total High Range 400 to 750 mg/L (as CaCO²) 1 mg/L ±10 mg/L ±2% of reading at 25 °C 466 nm 22 mm diameter Adaptation of the EPA Method 130.1 #043 HI93735-02 Reagents for 100 tests (HR) HI93735-0 Reagents for 300 tests (LR - 100 tests, MR - 100 tests, HR - 100 tests) Hydrazine 0 to 400 μg/L (as NºH¹) 1 μg/L ±3 μg/L ±3 % of reading at 25°C 466 nm 22 mm diameter Adaptation of the ASTM Manual of Water and Environmental Technology, Method D1385,p- Dimethylaminobenzaldehyde Method #044 HI93704-01 Reagents for 100 tests HI93704-03 Reagents for 300 tests Iodine 0.0 to 12.5 mg/L (as Iº) 0.1 mg/L ±0.1 mg/L ±5% of reading at 25 °C 525 nm 22 mm diameter Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, DPD Method #045 HI93718-01 Reagents for 100 tests HI93718-03 Reagents for 300 tests Iron Low Range 0.000 to 1.600 mg/L (as Fe) 0.001 mg/L ±0.010 mg/L ±8% of reading at 25 °C 575 nm 22 mm diameter Adaptation of the TPTZ Method #046 HI93746-01 Reagents for 50 tests HI93746-03 Reagents for 150 tests Iron High Range 0.00 to 5.00 mg/L (as Fe) 0.01 mg/L ±0.04 mg/L ±2% of reading at 25 °C 525 nm 22 mm diameter Adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method #047 HI93721-01 Reagents for 100 tests HI93721-03 Reagents for 300 tests Iron (II) (Ferrous) 0.00 to 6.00 mg/L (as Fe»+) 0.01 mg/L ±0.10 mg/L ±2% of reading at 25 °C 525 nm 22 mm diameter Adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method #089 HI96776-01 Reagents for 100 tests HI96776-03 Reagents for 300 tests Iron (13 mm Vial) 0.00 to 6.00 mg/L (as Fe) 0.01 mg/L ±0.10 mg/L or ±3% of reading at 25°C 525 nm 13 mm diameter Adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method #096 HI96786-25 Reagents for 25 tests Iron Total (13 mm Vial) 0.00 to 7.00 mg/L (as Fe) 0.01 mg/L ±0.20 mg/L or± 3% of reading, whichever is greater 525 nm 13 mm diameter Adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method #090 HI96778-25 Reagents for 25 tests Magnesium 0 to 150 mg/L (as Mg»+) 1 mg/L ±5 mg/L ±3% of reading at 25 °C 466 nm 22 mm diameter Adaptation of the Calmagite Method #048 HI937520-01 Reagents for 50 tests HI937520-03 Reagents for 150 tests Magnesium, Marine 1000 to 1800 mg/L (as Mg»+) 5 mg/L ±5% of reading 640 nm 22 mm diameter Adaptation of Colorimetric EDTA Method using calmagite indicator #103 HI783-25 Reagents for 25 tests Manganese Low Range 0 to 300 μg/L (as Mn) 1 μg/L ±7 μg/L ±3% of reading at 25 °C 560 nm 22 mm diameter Adaptation of the PAN Method #049 HI93748-01 Reagents for 50 tests HI93748-03 Reagents for 150 tests 10 Photometers 10.17 www.hannainst.com | iris® Spectrophotometer

RkJQdWJsaXNoZXIy MTI3NTM=