Parameter Range Resolution Accuracy Wavelength Cuvette Type Method Method ID Reagent Code Manganese High Range 0.0 to 20.0 mg/L (as Mn) 0.1 mg/L ±0.2 mg/L ±3% of reading at 25 °C 525 nm 22 mm diameter Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Periodate Method #050 HI93709-01 Reagents for 100 tests HI93709-03 Reagents for 300 tests Maple Syrup 0.00 to 100.00 %T 0.01 %T ±3% of reading at 25 °C 560 nm 10 mm diameter Direct Measure #051 HI93703-57 Glycerol (4 pcs.), 30 mL Molybdenum 0.0 to 40.0 mg/L (as MoÀ+) 0.1 mg/L ±0.3 mg/L ±5% of reading at 25 °C 420 nm 22 mm diameter Adaptation of the Mercaptoacetic Acid Method #052 HI93730-01 Reagents for 100 tests HI93730-03 Reagents for 300 tests Nickel Low Range 0.000 to 1.000 mg/L (as Ni) 0.001 mg/L ±0.010 mg/L ±7% of reading at 25 °C 565 nm 16 mm diameter Adaptation of the PAN Method #053 HI93740-01 Reagents for 50 tests HI93740-03 Reagents for 150 tests Nickel High Range 0.00 to 7.00 ppt (as Ni) 0.01 ppt ±0.07 ppt±4% of reading at 25 °C 575 nm 22 mm diameter Adaptation of the Photometric Method #054 HI93726-01 Reagents for 100 tests HI93726-03 Reagents for 300 tests Nitrate 0.0 to 30.0 mg/L (as NO²¯-N) 0.1 mg/L ±0.5 mg/L ±10% of reading at 25 °C 525 nm 22 mm diameter Adaptation of the Cadmium Reduction Method #055 HI93728-01 Reagents for 100 tests HI93728-03 Reagents for 300 tests Nitrate Chromotropic Acid (13 mm Vial) 0.0 to 30.0 mg/L (as N0²¯-N) 0.1 mg/L ±1.0 mg/L or ±3% of reading at 25 °C, whichever is greater 410 nm 13 mm diameter Chromotropic Acid Method #056 HI93766-50 Reagents for 50 tests Nitrate, Marine High Range 0.0 to 75.0 mg/L (as N0²¯) 0.1 mg/L ±2.0 mg/L ± 5 % of reading 505 nm 16 mm diameter Zinc Reduction Method #102 HI782-25 Reagents for 25 tests Nitrite Low Range 0 to 600 μg/L (as NOº¯-N) 1 μg/L ±20 μg/L ±4% of reading at 25 °C 480 nm 22 mm diameter Adaptation of the EPA Diazotization Method 354.1 #058 HI93707-01 Reagents for 100 tests HI93707-03 Reagents for 300 tests Nitrite Low Range (13 mm Vial) 0 to 600 μg/L (as NOº¯-N) 1 μg/L ±10 μg/L ± 3% of reading at 25°C, whichever is greater 525 nm 13 mm diameter Adaptation of the Standard Method for the Examination of Water and Wastewater, 23rd Edition, 4500B Diazotization Method, Nitrogen Nitrite #091 HI96783-25 Reagents for 25 tests Nitrite Medium Range (13 mm Vial) 0.00 to 6.00 mg/L (as NOº¯-N) 0.01 mg/L ±0.10 mg/L ± 3% of reading at 25°C 525 nm 13 mm diameter Adaptation of the Standard Method for the Examination of Water and Wastewater, 23rd Edition, 4500B Diazotization Method, Nitrogen Nitrite #092 HI96784-25 Reagents for 25 tests Nitrite High Range 0 to 150 mg/L (as NOº¯) 1 mg/L ±4 mg/L ±4% of reading at 25 °C 575 nm 22 mm diameter Adaptation of the Ferrous Sulfate Method #059 HI93708-01 Reagents for 100 tests HI93708-03 Reagents for 300 tests Nitrite, Marine Ultra Low Range 0 to 200 μg/L (as N0º¯-N) 1 μg/L ±8 μg/L ±4% of reading at 25 °C 480 nm 22 mm diameter Adaptation of the EPA Diazotization Method 354.1 #057 HI764-25 Reagents for 25 tests Nitrite, Marine (13 mm Vial) 0 to 600 μg/L (as N0º¯-N) 1 μg/L ±15 μg/L ±5% of reading at 25 °C 525 nm 13 mm diameter Adaptation of the Standard Method for the Examination of Water and Wastewater, 23rd Edition, 4500B Diazotization Method, Nitrogen Nitrite #098 HI96789-25 Reagents for 25 tests Nitrogen, Total Low Range (13 mm Vial) 0.0 to 25.0 mg/L (as N) 0.1 mg/L ±1.0 mg/L or ±5% of reading at 25 °C, whichever is greater 420 nm 13 mm diameter Chromotropic Acid Method #060 HI93767A-50 Reagents for up to 50 tests Nitrogen, Total High Range (13 mm Vial) 10 to 150 mg/L (as N) 1 mg/L ±3 mg/L or ±4% of reading at 25 °C, whichever is greater 420 nm 13 mm diameter Chromotropic Acid Method #061 HI93767B-50 Reagents for up to 50 tests 10 Photometers 10.18 | www.hannainst.com iris® Spectrophotometer
RkJQdWJsaXNoZXIy MTI3NTM=