HANNA® instruments Catálogo General v39

See page 10.128 for standard reagents; see page 10.41 for general accessories Parameter Range Resolution Accuracy Wavelength Method Reagent Code Aluminum 0.00 to 1.00 mg/L (as Al·+) 0.01 mg/L ±0.04 mg/L ±4% of reading at 25 °C 525 nm Adaptation of the Aluminon Method HI93712-01 Reagents for 100 tests HI93712-03 Reagents for 300 tests Ammonia Low Range 0.00 to 3.00 mg/L (as NH²-N) 0.01 mg/L ±0.04 mg/L ±4% of reading at 25 °C 420 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler Method HI93700-01 Reagents for 100 tests HI93700-03 Reagents for 300 tests Ammonia Medium Range 0.00 to 10.00 mg/L (as NH²-N) 0.01 mg/L ±0.05 mg/L ±5% of reading at 25 °C 420 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler Method HI93715-01 Reagents for 100 tests HI93715-03 Reagents for 300 tests Ammonia High Range 0.0 to 100.0 mg/L (as NH²-N) 0.1 mg/L ±0.5 mg/L ±5% of reading at 25 °C 420 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler Method HI93733-01 Reagents for 100 tests HI93733-03 Reagents for 300 tests Bromine 0.00 to 8.00 mg/L (as Brº) 0.01 mg/L ±0.08 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, DPD Method HI93716-01 Reagents for 100 tests HI93716-03 Reagents for 300 tests Chlorine Dioxide 0.00 to 2.00 mg/L (as ClOº) 0.01 mg/L ±0.10 mg/L ±5% of reading at 25 °C 575 nm Adaptation of the Chlorophenol Red Method HI93738-01 Reagents for 100 tests HI93738-03 Reagents for 300 tests Chlorine Dioxide (Rapid) 0.00 to 2.00 mg/L (as ClOº) 0.01 mg/L ±0.10 mg/L ±5% of reading at 25 °C 525 nm Adaptation of Standard Methods for the Examination of Water and Wastewater, 18th Edition, 4500 ClOºD HI96779-01 Reagents for 100 tests HI96779-03 Reagents for 300 tests Chlorine, Free 0.00 to 5.00 mg/L (as Clº) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the EPA DPD Method 330.5 HI93701-F 300 tests (liquid) HI93701-01 100tests (powder) HI93701-03 300tests (powder) Chlorine, Total 0.00 to 5.00 mg/L (as Clº) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the EPA DPD Method 330.5 HI93701-T 300 tests (liquid) HI93711-01 100 total tests (powder) HI93711-03 300 total tests (powder) Chromium (VI) Low Range 0 to 300 μg/L (as Cr(VI)) 1 μg/L ±10 μg/L ±4% of reading at 25 °C 525 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1687 Diphenylcarbohydrazide Method HI93749-01 Reagents for 100 tests HI93749-03 Reagents for 300 tests Chromium (VI) High Range 0 to 1000 μg/L (as Cr(VI)) 1 μg/L ±5 μg/L ±4% of reading at 25 °C 525 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide Method HI93723-01 Reagents for 100 tests HI93723-03 Reagents for 300 tests Copper Low Range 0.000 to 1.500mg/L (as Cu»+) 0.001mg/L ±0.010mg/L ±5% of reading at 25 °C 575 nm Adaptation of the EPA Method HI95747-01 Reagents for 100 tests HI95747-03 Reagents for 300 tests Copper High Range 0.00 to 5.00 mg/L (as Cu»+) 0.01 mg/L ±0.02 mg/L ±4% of reading at 25 °C 575 nm Adaptation of the EPA Method HI93702-01 Reagents for 100 tests HI93702-03 Reagents for 300 tests Hydrazine 0 to 400 μg/L (as NºH¹) 1 μg/L ±4% of full scale reading at 25 °C 466 nm Adaptation of the ASTM Manual of Water and Environmental Technology, Method D1385, p- Dimethylaminobenzaldehyde Method HI93704-01 Reagents for 100 tests HI93704-03 Reagents for 300 tests Iron Low Range 0.000 to 1.600 mg/L (as Fe) 0.001 mg/L ±0.010 mg/L ±8% of reading at 25 °C 575 nm Adaptation of the TPTZ Method HI93746-01 Reagents for 50 tests HI93746-03 Reagents for 150 tests Iron High Range 0.00 to 5.00 mg/L (as Fe) 0.01 mg/L ±0.04 mg/L ±2% of reading at 25 °C 525 nm Adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method HI93721-01 Reagents for 100 tests HI93721-03 Reagents for 300 tests Iron (II) 0.00 to 6.00 mg/L (as Fe»+) 0.01 mg/L ±0.10 mg/L ±2% of reading at 25 °C 525 nm Adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method HI96776-01 Reagents for 100 tests HI96776-03 Reagents for 300 tests Molybdenum 0.0 to 40.0 mg/L (as MoÀ+) 0.1 mg/L ±0.3 mg/L ±5% of reading at 25 °C 420 nm Adaptation of the Mercaptoacetic Acid Method HI93730-01 Reagents for 100 tests HI93730-03 Reagents for 300 tests Nitrate 0.0 to 30.0 mg/L (as NO²¯-N) 0.1 mg/L ±0.5 mg/L ±10% of reading at 25 °C 525 nm Adaptation of the Cadmium Reduction Method HI93728-01 Reagents for 100 tests HI93728-03 Reagents for 300 tests Nitrite Low Range 0 to 600 μg/L (as NOº¯-N) 1 μg/L ±20 μg/L ±4% of reading at 25 °C 466 nm Adaptation of the EPA Diazotization Method 354.1 HI93707-01 Reagents for 100 tests HI93707-03 Reagents for 300 tests Nitrite High Range 0 to 150 mg/L (as NOº¯) 1 mg/L ±4 mg/L ±4% of reading at 25 °C 575 nm Adaptation of the Ferrous Sulfate Method HI93708-01 Reagents for 100 tests HI93708-03 Reagents for 300 tests Oxygen, Dissolved 0.0 to 10.0 mg/L (as Oº) 0.1 mg/L ±0.4 mg/L ±3% of reading at 25 °C 420 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Azide Modified Winkler Method HI93732-01 Reagents for 100 tests HI93732-03 Reagents for 300 tests Oxygen Scavengers (Carbohydrazide) 0.00 to 1.50 mg/L (as Carbohydrazide) 0.01 mg/L ±0.02 mg/L ±3% of reading at 25 °C 575 nm Adaptation of the Iron Reduction Method HI96773-01 Reagents for 50 tests HI96773-03 Reagents for 150 tests Oxygen Scavengers (Diethylhydroxylamine) (DEHA) 0 to 1000 μg/L (as DEHA) 1 μg/L ±5 μg/L ±5% of reading at 25 °C 575 nm Adaptation of the Iron Reduction Method HI96773-01 Reagents for 50 tests HI96773-03 Reagents for 150 tests Oxygen Scavengers (Hydroquinone) 0.00 to 2.50 mg/L (as Hydroquinone) 0.01 mg/L ±0.04 mg/L ±3% of reading at 25 °C 575 nm Adaptation of Iron Reduction Method HI96773-01 Reagents for 50 tests HI96773-03 Reagents for 150 tests Oxygen Scavengers (Iso-ascorbic Acid) 0.00 to 4.50 mg/L (as Iso-Ascorbic Acid) 0.01 mg/L ±0.03 mg/L ±3 % of reading at 25 °C 575 nm Adaptation of the Iron Reduction Method HI96773-01 Reagents for 50 tests HI96773-03 Reagents for 150 tests pH 6.5 to 8.5 pH 0.1 pH ±0.1 pH at 25 °C 525 nm Adaptation of the Phenol Red Method HI93710-01 Reagents for 100 pH tests HI93710-03 Reagents for 300 pH tests Phosphate Low Range 0.00 to 2.50 mg/L (as PO¹·¯) 0.01 mg/L ±0.04 mg/L ±4% of reading at 25 °C 610 nm Adaptation of the Ascorbic Acid Method HI93713-01 Reagents for 100 tests HI93713-03 Reagents for 300 tests Phosphate High Range 0.0 to 30.0 mg/L (as PO¹·¯) 0.1 mg/L ±1.0 mg/L ±4% of reading at 25 °C 525 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Amino Acid Method HI93717-01 Reagents for 100 tests HI93717-03 Reagents for 300 tests Silica Low Range 0.00 to 2.00 mg/L (as SiOº) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 610 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue Method HI93705-01 Reagents for 100 tests HI93705-03 Reagents for 300 tests Silica High Range 0 to 200 mg/L (as SiOº) 1 mg/L ±1 mg/L ±5% of reading at 25 °C 466 nm Adaptation of the EPA Method 370.1 for Drinking, Surface and Saline Waters, Domestic and Industrial Wastes and Standard Method 4500-SiOº HI96770-01 Reagents for 100 tests HI96770-03 Reagents for 300 tests Zinc 0.00 to 3.00 mg/L (as Zn) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 575 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Zincon Method HI93731-01 Reagents for 100 tests HI93731-03 Reagents for 300 tests Ordering Information HI83305-01 (115V) and HI83305-02 (230V) is supplied with sample cuvette (4 pcs.), sample cuvette cap (4 pcs.), cloth for wiping cuvettes, scissors, USB cable, 5 Vdc power adapter, 60 mL glass bottle, instrument quality certificate, and instruction manual. Standards HI83305-11 CAL Check Cuvette Kit for HI83305 10 Photometers 10.49 www.hannainst.com | benchtop

RkJQdWJsaXNoZXIy MTI3NTM=