See page 10.128 for standard reagents; see page 10.41 for general accessories Parameter Range Resolution Accuracy Wavelength Method Reagent Code Ammonia Low Range 0.00 to 3.00 mg/L (as NH²-N) 0.01 mg/L ±0.04 mg/L ±4% of reading at 25 °C 420 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler Method HI93700-01 Reagents for 100 tests HI93700-03 Reagents for 300 tests Ammonia Medium Range 0.00 to 10.00 mg/L (as NH²-N) 0.01 mg/L ±0.05 mg/L ±5% of reading at 25 °C 420 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler Method HI93715-01 Reagents for 100 tests HI93715-03 Reagents for 300 tests Ammonia High Range 0.0 to 100.0 mg/L (as NH²-N) 0.1 mg/L ±0.5 mg/L ±5% of reading at 25 °C 420 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler Method HI93733-01 Reagents for 100 tests HI93733-03 Reagents for 300 tests Chlorine, Free 0.00 to 5.00 mg/L (as Clº) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the EPA DPD Method 330.5 HI93701-F Reagents for 300 tests (liquid) HI93701-01 Reagents for 100 tests (powder) HI93701-03 Reagents for 300 tests (powder) Chlorine, Total 0.00 to 5.00 mg/L (as Clº) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the EPA DPD Method 330.5 HI93701-T Reagents for 300 tests (liquid) HI93711-01 Reagents for 100 total tests (powder) HI93711-03 Reagents for 300 total tests (powder) Chromium (VI) Low Range 0 to 300 μg/L (as Cr(VI)) 1 μg/L ±10 μg/L ±4% of reading at 25 °C 525 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1687 Diphenylcarbohydrazide Method HI93749-01 Reagents for 100 tests HI93749-03 Reagents for 300 tests Chromium (VI) High Range 0 to 1000 μg/L (as Cr(VI)) 1 μg/L ±5 μg/L ±4% of reading at 25 °C 525 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide Method HI93723-01 Reagents for 100 tests HI93723-03 Reagents for 300 tests Color of Water 0 to 500 PCU (Platinum Cobalt Units) 1 PCU ±10 PCU ±5% of reading at 25 °C 420 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Colorimetric Platinum Cobalt Method — Copper Low Range 0.000 to 1.500mg/L (as Cu»+) 0.001mg/L ±0.010mg/L ±5% of reading at 25 °C 575 nm Adaptation of the EPA Method HI95747-01 Reagents for 100 tests HI95747-03 Reagents for 300 tests Copper High Range 0.00 to 5.00 mg/L (as Cu»+) 0.01 mg/L ±0.02 mg/L ±4% of reading at 25 °C 575 nm Adaptation of the EPA Method HI93702-01 Reagents for 100 tests HI93702-03 Reagents for 300 tests Cyanuric Acid 0 to 80 mg/L (as CYA) 1 mg/L ±1 mg/L ±15% of reading at 25 °C 525 nm Adaptation of the Turbidimetric Method HI93722-01 Reagents for 100 tests HI93722-03 Reagents for 300 tests Molybdenum 0.0 to 40.0 mg/L (as MoÀ+) 0.1 mg/L ±0.3 mg/L ±5% of reading at 25 °C 420 nm Adaptation of the Mercaptoacetic Acid Method HI93730-01 Reagents for 100 tests HI93730-03 Reagents for 300 tests Nickel Low Range 0.000 to 1.000 mg/L (as Ni) 0.001 mg/L ±0.010 mg/L ±7% of reading at 25 °C 575 nm Adaptation of the PAN Method HI93740-01 Reagents for 50 tests HI93740-03 Reagents for 150 tests Nickel High Range 0.00 to 7.00 g/L (as Ni) 0.01 g/L ±0.07 g/L ±4% of reading at 25 °C 575 nm Adaptation of the Photometric Method HI93726-01 Reagents for 100 tests HI93726-03 Reagents for 300 tests Nitrate 0.0 to 30.0 mg/L (as NO²¯-N) 0.1 mg/L ±0.5 mg/L ±10% of reading at 25 °C 525 nm Adaptation of the Cadmium Reduction Method HI93728-01 Reagents for 100 tests HI93728-03 Reagents for 300 tests Nitrite High Range 0 to 150 mg/L (as NOº¯) 1 mg/L ±4 mg/L ±4% of reading at 25 °C 575 nm Adaptation of the Ferrous Sulfate Method HI93708-01 Reagents for 100 tests HI93708-03 Reagents for 300 tests Oxygen, Dissolved 0.0 to 10.0 mg/L (as Oº) 0.1 mg/L ±0.4 mg/L ±3% of reading at 25 °C 420 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Azide Modified Winkler Method HI93732-01 Reagents for 100 tests HI93732-03 Reagents for 300 tests pH 6.5 to 8.5 pH 0.1 pH ±0.1 pH at 25 °C 525 nm Adaptation of the Phenol Red Method HI93710-01 Reagents for 100 pH tests HI93710-03 Reagents for 300 pH tests Phosphate Low Range 0.00 to 2.50 mg/L (as PO¹·¯) 0.01 mg/L ±0.04 mg/L ±4% of reading at 25 °C 610 nm Adaptation of the Ascorbic Acid Method HI93713-01 Reagents for 100 tests HI93713-03 Reagents for 300 tests Phosphate High Range 0.0 to 30.0 mg/L (as PO¹·¯) 0.1 mg/L ±1.0 mg/L ±4% of reading at 25 °C 525 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Amino Acid Method HI93717-01 Reagents for 100 tests HI93717-03 Reagents for 300 tests Silica Low Range 0.00 to 2.00 mg/L (as SiOº) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 610 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue Method HI93705-01 Reagents for 100 tests HI93705-03 Reagents for 300 tests Silver 0.000 to 1.000 mg/L (as Ag) 0.001 mg/L ±0.020 mg/L ±5% of reading at 25 °C 575 nm Adaptation of the PAN Method HI93737-01 Reagents for 50 tests HI93737-03 Reagents for 150 tests Zinc 0.00 to 3.00 mg/L (as Zn) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 575 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Zincon Method HI93731-01 Reagents for 100 tests HI93731-03 Reagents for 300 tests Ordering Information HI83306-01 (115V) and HI83306-02 (230V) is supplied with sample cuvette (4 pcs.), sample cuvette cap (4 pcs.), cloth for wiping cuvettes, scissors, USB cable, 5 Vdc power adapter, 60 mL glass bottle, instrument quality certificate, and instruction manual. Standards HI83306-11 CAL Check Cuvette Kit for HI83306 10 Photometers 10.51 www.hannainst.com | benchtop
RkJQdWJsaXNoZXIy MTI3NTM=