Supplied Complete HI83225 is supplied with the HI83300-100 in a rugged carrying case. See page 10.128 for standard reagents; see page 10.54 for Suction Lysimeter; see page 10.41for general accessories; Parameter Range Resolution Accuracy Wavelength Method Reagent Code Ammonia Low Range 0.00 to 3.00 mg/L (as NH²-N) 0.01 mg/L ±0.04 mg/L ±4% of reading at 25 °C 420 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler Method HI93700-01 Reagents for 100 tests HI93700-03 Reagents for 300 tests Ammonia Medium Range 0.00 to 10.00 mg/L (as NH²-N) 0.01 mg/L ±0.05 mg/L ±5% of reading at 25 °C 420 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler Method HI93715-01 Reagents for 100 tests HI93715-03 Reagents for 300 tests Ammonia High Range 0.0 to 100.0 mg/L (as NH²-N) 0.1 mg/L ±0.5 mg/L ±5% of reading at 25 °C 420 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler Method HI93733-01 Reagents for 100 tests HI93733-03 Reagents for 300 tests Calcium 0 to 400 mg/L (as Ca»+) 1 mg/L ±10 mg/L ±5% of reading at 25 °C 466 nm Adaptation of the Oxalate Method HI937521-01 Reagents for 50 tests HI937521-03 Reagents for 150 tests Iron(II)/(III) 0.00 to 6.00mg/L (as Fe) 0.01mg/L ±0.10 mg/L ±2% of reading at 25°C 525 nm Adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method HI96777-01 Reagents for 100tests HI96777-03 Reagents for 300tests Magnesium 0 to 150 mg/L (as Mg»+) 1 mg/L ±5 mg/L ±3% of reading at 25 °C 466 nm Adaptation of the Calmagite Method HI937520-01 Reagents for 50 tests HI937520-03 Reagents for 150 tests Nitrate 0.0 to 30.0 mg/L (as NO²¯-N) 0.1 mg/L ±0.5 mg/L ±10% of reading at 25 °C 525 nm Adaptation of the Cadmium Reduction Method HI93728-01 Reagents for 100 tests HI93728-03 Reagents for 300 tests Phosphate High Range 0.0 to 30.0 mg/L (as PO¹·¯) 0.1 mg/L ±1.0 mg/L ±4% of reading at 25 °C 525 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Amino Acid Method HI93717-01 Reagents for 100 tests HI93717-03 Reagents for 300 tests Potassium 0.0 to 20.0 mg/L (as K) 0.1 mg/L ±3 mg/L ±7% of reading at 25 °C 466 nm Adaptation of the Turbidimetric Tetraphenylborate Method HI93750-01 Reagents for 100 tests HI93750-03 Reagents for 300 tests Sulfate 0 to 150 mg/L (as SO¹»¯) 1 mg/L ±5 mg/L ±3% of reading at 25 °C 466 nm Sulfate is precipitated with barium chloride crystals HI93751-01 Reagents for 100 tests HI93751-03 Reagents for 300 tests Ordering Information HI83325-01 (115V) and HI83325-02 (230V) is supplied with sample cuvette (4 pcs.), sample cuvette cap (4 pcs.), cloth for wiping cuvettes, scissors, 100 mL plastic graduated beaker with cap, 170 mL plastic graduated beaker, 3 mL plastic pipette, 5 mL graduated syringe, 60 mL graduated syringe, graduated cylinder, spoon, funnel, filter paper, demineralizer bottle for 10 L of water, activated carbon for 50 tests, USB cable, 5 Vdc power adapter, instrument quality certificate, and instruction manual. Standards HI83325-11 CAL Check Cuvette Kit for HI83325 10 Photometers 10.53 www.hannainst.com | benchtop
RkJQdWJsaXNoZXIy MTI3NTM=