HANNA® instruments Catálogo General v39

• Digital pH Electrode Input · Measure pH and temperature with a single probe · Good Laboratory Practice (GLP) to track calibration information including date, time, buffers used, offset and slope for traceability · pH CAL Check™ alerts user to potential problems during the calibration process · Space saving having a pH meter and photometer built into one meter See page 10.128 for standard reagents; see page 10.41 for general accessories Parameter Range Resolution Accuracy Wavelength Method Reagent Code Alkalinity 0 to 500 mg/L (as CaCO²) 1 mg/L ±5 mg/L ±5% of reading at 25 °C 610 nm Bromocresol Green HI775-26 Reagents for 25 tests Bromine 0.00 to 8.00 mg/L (as Brº) 0.01 mg/L ±0.08 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, DPD Method HI93716-01 Reagents for 100 tests HI93716-03 Reagents for 300 tests Chlorine Dioxide 0.00 to 2.00 mg/L (as ClOº) 0.01 mg/L ±0.10 mg/L ±5% of reading at 25 °C 575 nm Adaptation of the Chlorophenol Red Method HI93738-01 Reagents for 100 tests HI93738-03 Reagents for 300 tests Chlorine Dioxide (Rapid) 0.00 to 2.00 mg/L (as ClOº) 0.01 mg/L ±0.10 mg/L ±5% of reading at 25 °C 525 nm Adaptation of Standard Methods for the Examination of Water and Wastewater, 18th Edition, 4500 ClOºD HI96779-01 Reagents for 100 tests HI96779-03 Reagents for 300 tests Chlorine, Free 0.00 to 5.00 mg/L (as Clº) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the EPA DPD Method 330.5 HI93701-F 300 tests (liquid) HI93701-01 100 tests (powder) HI93701-03 300 tests (powder) Chlorine, Total 0.00 to 5.00 mg/L (as Clº) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the EPA DPD Method 330.5 HI93701-T 300 tests (liquid) HI93711-01 100 total tests (powder) HI93711-03 300 total tests (powder) Copper High Range 0.00 to 5.00 mg/L (as Cu»+) 0.01 mg/L ±0.02 mg/L ±4% of reading at 25 °C 575 nm Adaptation of the EPA Method HI93702-01 Reagents for 100 tests HI93702-03 Reagents for 300 tests Cyanuric Acid 0 to 80 mg/L (as CYA) 1 mg/L ±1 mg/L ±15% of reading at 25 °C 525 nm Adaptation of the Turbidimetric Method HI93722-01 Reagents for 100 tests HI93722-03 Reagents for 300 tests Hardness, Calcium 0.00 to 2.70 mg/L (as CaCO²) 0.01 mg/L ±0.11 mg/L ±5% of reading at 25 °C 525 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Calmagite Method HI93720-01 Reagents for 100 tests HI93720-03 Reagents for 300 tests Iron High Range 0.00 to 5.00 mg/L (as Fe) 0.01 mg/L ±0.04 mg/L ±2% of reading at 25 °C 525 nm Adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method HI93721-01 Reagents for 100 tests HI93721-03 Reagents for 300 tests Nitrate 0.0 to 30.0 mg/L (as NO²¯-N) 0.1 mg/L ±0.5 mg/L ±10% of reading at 25 °C 525 nm Adaptation of the Cadmium Reduction Method HI93728-01 Reagents for 100 tests HI93728-03 Reagents for 300 tests Ozone 0.00 to 2.00 mg/L (as O²) 0.01 mg/L ±0.02 mg/L ±3% of reading at 25 °C 525 nm Colorimetric DPD Method HI93757-01 Reagents for 100 tests HI93757-03 Reagents for 300 tests HI93703-52 Reagents for 100 tests (Optional) pH 6.5 to 8.5 pH 0.1 pH ±0.1 pH at 25 °C 525 nm Adaptation of the Phenol Red Method HI93710-01 Reagents for 100 pH tests HI93710-03 Reagents for 300 pH tests Phosphate Low Range 0.00 to 2.50 mg/L (as PO¹·¯) 0.01 mg/L ±0.04 mg/L ±4% of reading at 25 °C 610 nm Adaptation of the Ascorbic Acid Method HI93713-01 Reagents for 100 tests HI93713-03 Reagents for 300 tests Ordering Information HI83326-01 (115V) and HI83326-02 (230V) is supplied with sample cuvette (4 pcs.), sample cuvette cap (4 pcs.), cloth for wiping cuvettes, scissors, 100 mL graduated beaker, USB cable, 5 Vdc power adapter, instrument quality certificate, and instruction manual. Standards HI83326-11 CAL Check Cuvette Kit for HI83326 10 Photometers 10.59 www.hannainst.com | benchtop

RkJQdWJsaXNoZXIy MTI3NTM=