HANNA® instruments Catálogo General v39

benchtop Specifications HI83224 Light Life Life of the instrument Light Detector Silicon Photocell Data Logging up to 200 samples PC Connectivity USB Environment 0 to 50 °C (32 to 122 °F); max 90% RH non-condensing Power Supply 230 VAC or 115 VAC Dimensions 235 x 212 x 143 mm (9.2 x 8.34 x 5.62”) Weight 2.3 kg (5.1 lb) Ordering Information HI83224-01 (115V) andHI83224-02 (230V) are supplied with sample vials (10), cloth for wiping vials (1 pcs.), scissors, and instruction manual. Notes: ‡ Method with chromium-sulfuric acid is officially recognized by EPA for wastewater analysis. ◊ The HI94754F-25 and HI94754G-25 method follows the official method ISO 15705. ◊◊This method is recommended for general purpose analysis with no chloride interference. • Bar code reader detects the method and range automatically Parameter Range Resolution Accuracy Wavelength Method Reagent Code Ammonia Low Range 0.00 to 3.00 mg/L (as NH®-N) 0.01 mg/L ±0.10 mg/L ±5% of reading at 25 °C 420 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler Method HI94764A-25 (25 tests) Ammonia High Range 0 to 100 mg/L (as NH®-N) 1 mg/L ±1 mg/L or ±5 % of reading @ 25 °C, whichever is greater 420 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler Method HI94764B-25 (25 tests) Chlorine, Free 0.00 to 5.00 mg/L (as Cl±) 0.01 mg/L ±0.03 mg/L ±4% of reading at 25 °C whichever is greater 525 nm Adaptation of the EPA method 330.5 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-Cl G, DPD method. HI93701-01 Reagents for 100 tests (powder) HI93701-03 Reagents for 300 tests (powder) Chlorine, Total 0.00 to 5.00 mg/L (as Cl±) 0.01 mg/L ±0.03 mg/L ±4% of reading at 25 °C whichever is greater 525 nm Adaptation of the EPA method 330.5 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-Cl G, DPD method. HI93711-01 Reagents for 100 total tests (powder) HI93711-03 Reagents for 300 total tests (powder) Chemical Oxygen Demand Low Range 0 to 150 mg/L (as O±) 1 mg/L ±5 mg/L or ±5% of reading at 25 °C, whichever is greater 420 nm dichromate EPA‡ dichromate mercury-free ◊◊ dichromate ISO ◊ HI94754A-25 Reagents EPA (25 tests) HI94754D-25 Reagents Hg Free (25 tests) HI94754F-25 Reagents ISO (25 tests) Chemical Oxygen Demand Medium Range 0 to 1500 mg/L (as O±) 1 mg/L ±15 mg/L or ±4% of reading at 25 °C, whichever is greater 610 nm dichromate EPA‡ dichromate mercury-free ◊◊ dichromate ISO ◊ HI94754B-25 Reagents EPA (25 tests) HI94754E-25 Reagents Hg Free (25 tests) HI94754G-25 Reagents ISO (25 tests) Chemical Oxygen Demand High Range 0 to 15000 mg/L (as O±) 10 mg/L ±150 mg/L or ±3% of reading at 25 °C, whichever is greater 610 nm dichromate HI94754C-25 Reagents for 24 tests Nitrate 0.0 to 30.0 mg/L (as N0±¯-N) 0.1 mg/L ±1.0 mg/L or ±5% of reading at 25 °C, whichever is greater 420 nm Chromotropic Acid Method HI94766-50 Reagents for up to 50 tests Nitrogen, Total Low Range 0.0 to 25.0 mg/L (as N) 0.1 mg/L ±1.0 mg/L or ±5% of reading at 25 °C, whichever is greater 420 nm Chromotropic Acid Method HI94767A-50 Reagents for up to 49 tests Nitrogen, Total High Range 10 to 150 mg/L (as N) 1 mg/L ±3 mg/L or ±4% of reading at 25 °C, whichever is greater 420 nm Chromotropic Acid Method HI94767B-50 Reagents for up to 49 tests Phosphorus, Acid Hydrolyzable (13 mm Vial) 0.00 to 1.60 mg/L (as P) 0.01 mg/L ±0.05 mg/L or ±5% of reading at 25 °C, whichever is greater 610 nm Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th Edition, 4500-P E, Ascorbic Acid Method HI94758B-50 (50 tests) Phosphorus, Reactive Low Range 0.00 to 1.60 mg/L (as P) 0.01 mg/L ±0.05 mg/L or ±5% of reading at 25 °C, whichever is greater 610 nm Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th Edition, 4500-P E, Ascorbic Acid Method HI94758A-50 (50 tests) Phosphorus, Reactive High Range 0.0 to 32.6 mg/L (as P) 0.1 mg/L ±0.5 mg/L or ±5% of reading at 25 °C, whichever is greater 420 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th Edition, 4500-P C, Vanadomolybdophosphoric Acid Method HI94763A-50 (49 tests) Phosphorus, Total Low Range 0.00 to 1.15mg/L (as P) 0.01 mg/L ±0.05 mg/L or ±6% of reading at 25 °C, whichever is greater 610 nm Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th Edition, 4500-P E, Ascorbic Acid Method HI94758C-50 (50 tests) Phosphorus, Total High Range 0.0 to 32.6 mg/L (as P) 0.1 mg/L ±0.5 mg/L or ±5% of reading at 25 °C, whichever is greater 420 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th Edition, 4500-P C, Vanadomolybdophosphoric Acid Method HI94763B-50 (49 tests) HI83224 Parameter Specifications 11 COD and Vials 11.5 www.hannainst.com |

RkJQdWJsaXNoZXIy MTI3NTM=