HANNA® instruments Catálogo General v39

Parameter Range Resolution Accuracy Wavelength Method Reagent Code Chemical Oxygen Demand Low Range (13 mm Vial) 0 to 150 mg/L (as O±) 1 mg/L ±5 mg/L or ±4% of reading at 25 °C, whichever is greater 420 nm Adaptation of the EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters HI93754A-25 Reagents EPA Low Range for 25 tests HI93754D-25 Reagents Hg Free Low Range for 25 tests HI93754F-25 Reagents ISO Low Range for 25 tests Chemical Oxygen Demand Medium Range (13 mm Vial) 0 to 1500 mg/L (as O±) 1 mg/L ±15 mg/L or ±4% of reading at 25 °C, whichever is greater 610 nm Adaptation of the EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters HI93754B-25 Reagents EPA Medium Range for 25 tests HI93754E-25 Reagents Hg Free Medium Range for 25 tests HI93754G-25 Reagents ISO Medium Range for 25 tests Chemical Oxygen Demand High Range EPA (13 mm Vial) 0 to 15000 mg/L (as O±) 1 mg/L ±150 mg/L or ±2% of reading at 25 °C, whichever is greater 610 nm Adaptation of the EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters HI93754C-25 Reagents for 25 tests Chemical Oxygen Demand Ultra High Range (13 mm Vial) 0.0 to 60.0 ppt (as O±) 0.1 ppt ±0.5 ppt ±3% of reading @ 25°C 610 nm Adaptation of the EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters HI93754J-25 Reagents for 25 tests Color of Water 0 to 500 PCU (Platinum Cobalt Units) 1 PCU ±10 PCU ±5% of reading at 25 °C 420 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Colorimetric Platinum Cobalt Method — Copper Low Range 0.000 to 1.500mg/L (as CuÀ+) 0.001mg/L ±0.010mg/L ±5% of reading at 25 °C 575 nm Adaptation of the EPA Method HI95747-01 Reagents for 100 tests HI95747-03 Reagents for 300 tests Copper High Range 0.00 to 5.00 mg/L (as CuÀ+) 0.01 mg/L ±0.02 mg/L ±4% of reading at 25 °C 575 nm Adaptation of the EPA Method HI93702-01 Reagents for 100 tests HI93702-03 Reagents for 300 tests Cyanuric Acid 0 to 80 mg/L (as CYA) 1 mg/L ±1 mg/L ±15% of reading at 25 °C 525 nm Adaptation of the Turbidimetric Method HI93722-01 Reagents for 100 tests HI93722-03 Reagents for 300 tests Fluoride Low Range 0.00 to 2.00 mg/L (as F - ) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 575 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, SPADNS Method HI93729-01 Reagents for 100 tests HI93729-03 Reagents for 300 tests Fluoride High Range 0.0 to 20.0 mg/L (as F - ) 0.1 mg/L ±0.5 mg/L ±3% of reading at 25 °C 575 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, SPADNS Method HI93739-01 Reagents for 100 tests HI93739-03 Reagents for 300 tests Hardness, Calcium 0.00 to 2.70 mg/L (as CaCO®) 0.01 mg/L ±0.11 mg/L ±5% of reading at 25 °C 525 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Calmagite Method HI93720-01 Reagents for 100 tests HI93720-03 Reagents for 300 tests Hardness, Magnesium 0.00 to 2.00 mg/L (as CaCO®) 0.01 mg/L ±0.11 mg/L ±5% of reading at 25 °C 525 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, EDTA Colorimetric Method HI93719-01 Reagents for 100 tests HI93719-03 Reagents for 300 tests Hardness, Total Low Range 0 to 250 mg/L (as CaCO®) 1 mg/L ±5 mg/L ±4% of reading at 25 °C 466 nm Adaptation of the EPA Method 130.1 HI93735-00 Reagents for 100 tests (LR, 0 to 250mg/L) HI93735-0 Reagents for 300 tests (LR - 100 tests, MR - 100 tests, HR - 100 tests) Hardness, Total Medium Range 200 to 500 mg/L (as CaCO®) 1 mg/L ±7 mg/L ±3% of reading at 25 °C 466 nm Adaptation of the EPA Method 130.1 HI93735-01 Reagents for 100 tests (MR, 200 to 500mg/L) HI93735-0 Reagents for 300tests (LR - 100 tests, MR - 100 tests, HR - 100tests) Hardness, Total High Range 400 to 750 mg/L (as CaCO®) 1 mg/L ±10 mg/L ±2% of reading at 25 °C 466 nm Adaptation of the EPA Method 130.1 HI93735-02 Reagents for 100 tests (HR, 400 to 750mg/L) HI93735-0 Reagents for 300 tests (LR - 100 tests, MR - 100 tests, HR - 100 tests) Hydrazine 0 to 400 μg/L (as N±HÃ) 1 μg/L ±4% of full scale reading at 25 °C 466 nm Adaptation of the ASTM Manual of Water and Environmental Technology, Method D1385, p- Dimethylaminobenzaldehyde Method HI93704-01 Reagents for 100 tests HI93704-03 Reagents for 300 tests Iodine 0.0 to 12.5 mg/L (as I±) 0.1 mg/L ±0.1 mg/L ±5% of reading at 25 °C 525 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, DPD Method HI93718-01 Reagents for 100 tests HI93718-03 Reagents for 300 tests Iron Low Range 0.000 to 1.600 mg/L (as Fe) 0.001 mg/L ±0.010 mg/L ±8% of reading at 25 °C 575 nm Adaptation of the TPTZ Method HI93746-01 Reagents for 50 tests HI93746-03 Reagents for 150 tests Iron High Range 0.00 to 5.00 mg/L (as Fe) 0.01 mg/L ±0.04 mg/L ±2% of reading at 25 °C 525 nm Adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method HI93721-01 Reagents for 100 tests HI93721-03 Reagents for 300 tests 11 COD and Vials 11.12 | www.hannainst.com benchtop

RkJQdWJsaXNoZXIy MTI3NTM=