Parameter Range Resolution Accuracy Wavelength Method Reagent Code Iron (II) 0.00 to 6.00 mg/L (as FeÀ+) 0.01 mg/L ±0.10 mg/L ±2% of reading at 25 °C 525 nm Adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method HI96776-01 Reagents for 100 tests HI96776-03 Reagents for 300 tests Iron(II)/(III) 0.00 to 6.00mg/L (as Fe) 0.01mg/L ±0.10 mg/L ±2% of reading at 25°C 525 nm Adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method HI96777-01 Reagents for 100tests HI96777-03 Reagents for 300tests Iron (13 mm Vial) 0.00 to 6.00 mg/L (as Fe) 0.01 mg/L ±0.10 mg/L or ±3% of reading at 25°C 525 nm Adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method HI96786-25 Reagents for 25 tests Iron Total (13 mm Vial) 0.00 to 7.00 mg/L (as Fe) 0.01 mg/L ±0.20 mg/L or± 3% of reading, whichever is greater 525 nm Adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method HI96778-25 Reagents for 25 tests Magnesium 0 to 150 mg/L (as MgÀ+) 1 mg/L ±5 mg/L ±3% of reading at 25 °C 466 nm Adaptation of the Calmagite Method HI937520-01 Reagents for 50 tests HI937520-03 Reagents for 150 tests Manganese Low Range 0 to 300 μg/L (as Mn) 1 μg/L ±10 μg/L ±3% of reading at 25 °C 575 nm Adaptation of the PAN Method HI93748-01 Reagents for 50 tests HI93748-03 Reagents for 150 tests Manganese High Range 0.0 to 20.0 mg/L (as Mn) 0.1 mg/L ±0.2 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Periodate Method HI93709-01 Reagents for 100 tests HI93709-03 Reagents for 300 tests Molybdenum 0.0 to 40.0 mg/L (as MoÄ+) 0.1 mg/L ±0.3 mg/L ±5% of reading at 25 °C 420 nm Adaptation of the Mercaptoacetic Acid Method HI93730-01 Reagents for 100 tests HI93730-03 Reagents for 300 tests Nickel Low Range 0.000 to 1.000 mg/L (as Ni) 0.001 mg/L ±0.010 mg/L ±7% of reading at 25 °C 575 nm Adaptation of the PAN Method HI93740-01 Reagents for 50 tests HI93740-03 Reagents for 150 tests Nickel High Range 0.00 to 7.00 g/L (as Ni) 0.01 g/L ±0.07 g/L ±4% of reading at 25 °C 575 nm Adaptation of the Photometric Method HI93726-01 Reagents for 100 tests HI93726-03 Reagents for 300 tests Nitrate 0.0 to 30.0 mg/L (as NO®¯-N) 0.1 mg/L ±0.5 mg/L ±10% of reading at 25 °C 525 nm Adaptation of the Cadmium Reduction Method HI93728-01 Reagents for 100 tests HI93728-03 Reagents for 300 tests Nitrate (13 mm Vial) 0.0 to 30.0 mg/L (as N0®¯-N) 0.1 mg/L ±1.0 mg/L or ±3% of reading at 25 °C, whichever is greater 420 nm Chromotropic Acid Method HI93766-50 Reagents for 50 tests Nitrite, Marine (13 mm Vial) 0 to 600 μg/L (as N0±¯-N) 1 μg/L ±15 μg/L ±5% of reading at 25 °C 525 nm Adaptation of the Standard Method for the Examination of Water and Wastewater, 23th Edition, 4500B Diazotization Method, Nitrogen Nitrite HI96789-25 Reagents for 25 tests Nitrite, Marine Ultra Low Range 0 to 200 μg/L (as N0±¯-N) 1 μg/L ±10 μg/L ±4% of reading at 25 °C 466 nm Adaptation of the EPA Diazotization Method 354.1 HI764-25 Reagents for 25 tests Nitrite Low Range 0 to 600 μg/L (as NO±¯-N) 1 μg/L ±20 μg/L ±4% of reading at 25 °C 466 nm Adaptation of the EPA Diazotization Method 354.1 HI93707-01 Reagents for 100 tests HI93707-03 Reagents for 300 tests Nitrite Low Range (13 mm Vial) 0 to 600 μg/L (as NO±¯-N) 1 μg/L ±10 μg/L ± 3% of reading at 25°C, whichever is greater 525 nm Adaptation of the Standard Method for the Examination of Water and Wastewater, 23rd Edition, 4500B Diazotization Method, Nitrogen Nitrite HI96783-25 Reagents for 25 tests Nitrite Medium Range (13 mm Vial) 0.00 to 6.00 mg/L (as NO±¯-N) 0.01 mg/L ±0.10 mg/L ± 3% of reading at 25°C 525 nm Adaptation of the Standard Method for the Examination of Water and Wastewater, 23rd Edition, 4500B Diazotization Method, Nitrogen Nitrite HI96784-25 Reagents for 25 tests Nitrite High Range 0 to 150 mg/L (as NO±¯) 1 mg/L ±4 mg/L ±4% of reading at 25 °C 575 nm Adaptation of the Ferrous Sulfate Method HI93708-01 Reagents for 100 tests HI93708-03 Reagents for 300 tests Nitrogen, Total Low Range (13 mm Vial) 0.0 to 25.0 mg/L (as N) 0.1 mg/L ±1.0 mg/L or ±5% of reading at 25 °C, whichever is greater 420 nm Chromotropic Acid Method HI93767A-50 Reagents for up to 49 tests Nitrogen, Total High Range (13 mm Vial) 10 to 150 mg/L (as N) 1 mg/L ±3 mg/L or ±4% of reading at 25 °C, whichever is greater 420 nm Chromotropic Acid Method HI93767B-50 Reagents for up to 49 tests Oxygen, Dissolved 0.0 to 10.0 mg/L (as O±) 0.1 mg/L ±0.4 mg/L ±3% of reading at 25 °C 420 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Azide Modified Winkler Method HI93732-01 Reagents for 100 tests HI93732-03 Reagents for 300 tests Oxygen Scavengers (Carbohydrazide) 0.00 to 1.50 mg/L (as Carbohydrazide) 0.01 mg/L ±0.02 mg/L ±3% of reading at 25 °C 575 nm Adaptation of the Iron Reduction Method HI96773-01 Reagents for 50 tests HI96773-03 Reagents for 150 tests Oxygen Scavengers (Diethylhydroxylamine) (DEHA) 0 to 1000 μg/L (as DEHA) 1 μg/L ±5 μg/L ±5% of reading at 25 °C 575 nm Adaptation of the Iron Reduction Method HI96773-01 Reagents for 50 tests HI96773-03 Reagents for 150 tests Oxygen Scavengers (Hydroquinone) 0.00 to 2.50 mg/L (as Hydroquinone) 0.01 mg/L ±0.04 mg/L ±3% of reading at 25 °C 575 nm Adaptation of Iron Reduction Method HI96773-01 Reagents for 50 tests HI96773-03 Reagents for 150 tests Oxygen Scavengers (Iso-ascorbic Acid) 0.00 to 4.50 mg/L (as Iso-Ascorbic Acid) 0.01 mg/L ±0.03 mg/L ±3 % of reading at 25 °C 575 nm Adaptation of the Iron Reduction Method HI96773-01 Reagents for 50 tests HI96773-03 Reagents for 150 tests 11 COD and Vials 11.13 www.hannainst.com | benchtop
RkJQdWJsaXNoZXIy MTI3NTM=