HANNA® instruments Catálogo General v39

Parameter Range Resolution Accuracy Wavelength Method Reagent Code Ozone 0.00 to 2.00 mg/L (as O®) 0.01 mg/L ±0.02 mg/L ±3% of reading at 25 °C 525 nm Colorimetric DPD Method HI93757-01 Reagents for 100 tests HI93757-03 Reagents for 300 tests HI93703-52 Reagents for 100 tests (Optional) pH 6.5 to 8.5 pH 0.1 pH ±0.1 pH at 25 °C 525 nm Adaptation of the Phenol Red Method HI93710-01 Reagents for 100 pH tests HI93710-03 Reagents for 300 pH tests Phenols (13 mm Vial) 0.00 to 5.00 mg/L 0.01 mg/L ±0.05 mg/L ±3 % of reading at 25 °C 525 nm Adaptation of 4-aminoantipyrine method EPA 420.1 HI96788-25 Reagents for 25 tests Phosphate, Marine Ultra Low Range 0 to 200 μg/L (as P) 1 μg/L ±5 μg/L ±5% of reading at 25 °C 610 nm Adaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Acid Method HI736-25 Reagents for 25 tests Phosphate Low Range 0.00 to 2.50 mg/L (as POþ¯) 0.01 mg/L ±0.04 mg/L ±4% of reading at 25 °C 610 nm Adaptation of the Ascorbic Acid Method HI93713-01 Reagents for 100 tests HI93713-03 Reagents for 300 tests Phosphate High Range 0.0 to 30.0 mg/L (as POþ¯) 0.1 mg/L ±1.0 mg/L ±4% of reading at 25 °C 525 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Amino Acid Method HI93717-01 Reagents for 100 tests HI93717-03 Reagents for 300 tests Phosphorus, Acid Hydrolyzable (13 mm Vial) 0.00 to 1.60 mg/L (as P) 0.01 mg/L ±0.05 mg/L or ±5% of reading at 25 °C, whichever is greater 610 nm Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th Edition, 4500-P E, Ascorbic Acid Method HI93758B-50 Reagents for 50 tests Phosphorus, Reactive Low Range (13 mm Vial) 0.00 to 1.60 mg/L (as P) 0.01 mg/L ±0.05 mg/L or ±4% of reading at 25 °C, whichever is greater 610 nm Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th Edition, 4500-P E, Ascorbic Acid Method HI93758A-50 Reagents for 50 tests Phosphorus, Reactive High Range (13 mm Vial) 0.0 to 32.6 mg/L (as P) 0.1 mg/L ±0.5 mg/L or ±4% of reading at 25 °C, whichever is greater 420 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th Edition, 4500-P C, Vanadomolybdophosphoric Acid Method HI93763A-50 Reagents for up to 49 tests Phosphorus, Total Low Range (13 mm Vial) 0.00 to 1.15mg/L (as P 0.01 mg/L ±0.05 mg/L or ±6% of reading at 25 °C, whichever is greater 610 nm Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th Edition, 4500-P E, Ascorbic Acid Method HI93758C-50 Reagents for 50 tests Phosphorus, Total High Range (13 mm Vial) 0.0 to 32.6 mg/L (as P) 0.1 mg/L ±0.5 mg/L or ±5% of reading at 25 °C, whichever is greater 420 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th Edition, 4500-P C, Vanadomolybdophosphoric Acid Method HI93763B-50 Reagents for up to 49 tests Potassium 0.0 to 20.0 mg/L (as K) 0.1 mg/L ±3 mg/L ±7% of reading at 25 °C 466 nm Adaptation of the Turbidimetric Tetraphenylborate Method HI93750-01 Reagents for 100 tests HI93750-03 Reagents for 300 tests Silica Low Range 0.00 to 2.00 mg/L (as SiO±) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 610 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue Method HI93705-01 Reagents for 100 tests HI93705-03 Reagents for 300 tests Silica High Range 0 to 200 mg/L (as SiO±) 1 mg/L ±1 mg/L ±5% of reading at 25 °C 466 nm Adaptation of the EPA Method 370.1 for Drinking, Surface and Saline Waters, Domestic and Industrial Wastes and Standard Method 4500-SiO± HI96770-01 Reagents for 100 tests HI96770-03 Reagents for 300 tests Silver 0.000 to 1.000 mg/L (as Ag) 0.001 mg/L ±0.020 mg/L ±5% of reading at 25 °C 575 nm Adaptation of the PAN Method HI93737-01 Reagents for 50 tests HI93737-03 Reagents for 150 tests Sulfate 0 to 150 mg/L (as SOÃÀ¯) 1 mg/L ±5 mg/L ±3% of reading at 25 °C 466 nm Sulfate is precipitated with barium chloride crystals HI93751-01 Reagents for 100 tests HI93751-03 Reagents for 300 tests Surfactants, Anionic 0.00 to 3.50 mg/L (as SDBS) 0.01 mg/L ±0.04 mg/L ±3% of reading at 25 °C 610 nm Adaptation of the EPA Method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th Edition, 5540C, Anionic Surfactants as MBAS HI95769-01 Reagents for 40 tests Surfactants, Anionic (13 mm Vial) 0.00 to 3.50 mg/L (as SDBS) 0.01 mg/L ±0.10 mg/L ±5% of reading at 25 °C 610 nm Adaptation of the Standard Method for the Examination of Water and Wastewater, 23rd Edition, 5540C, Anionic Surfactants as MBAS HI96782-25 Reagents for 25 tests Surfactants, Cationic (13 mm Vial) 0.00 to 2.50 mg/L (as CTAB) 0.01 mg/L ±0.15 ppm ±3% of reading at 25°C 420 nm Bromophenol Blue Method HI96785-25 Reagents for 25 tests Surfactants, Nonionic (13 mm Vial) 0.00 to 6.00 mg/L (TRITON X-100) 0.01 mg/L ±0.10 mg/L ±5% of reading at 25 °C 610 nm TBPE Method HI96780-25 Reagents for 24 tests Zinc 0.00 to 3.00 mg/L (as Zn) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 575 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Zincon Method HI93731-01 Reagents for 100 tests HI93731-03 Reagents for 300 tests 11 COD and Vials 11.14 | www.hannainst.com benchtop

RkJQdWJsaXNoZXIy MTI3NTM=