HANNA® instruments Catálogo General v39

HI83414 Turbidity Specifications Non-Ratio Mode Range 0.00 to 9.99; 10.0 to 40.0 NTU 0.0 to 99.9; 100 to 268 Nephelos 0.00 to 9.80 EBC Resolution 0.01; 0.1 NTU 0.1; 1 Nephelos 0.01 EBC Ratio Mode Range 0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU 0.0 to 99.9; 100 to 26800 Nephelos 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC Resolution 0.01; 0.1; 1 NTU 0.1; 1 Nephelos 0.01; 0.1, 1 EBC Range Selection automatic Accuracy ±2% of reading plus 0.02 NTU (0.15 Nephelos; 0.01 EBC); ±5% of reading above 1000 NTU (6700 Nephelos; 245 EBC) Repeatability ±1% of reading or 0.02 NTU (0.15 Nephelos; 0.01 EBC) whichever is greater Stray Light < 0.02 NTU (0.15 Nephelos; 0.01 EBC) Light Detector silicon photocell Method nephelometric method (90°) or ratio nephelometric method (90° & 180°), adaptation of the USEPA method 180.1 and standard method 2130 B Measuring Mode normal, average, continuous Turbidity Standards <0.1, 15, 100, 750 and 2000 NTU Calibration two, three, four or five-point calibration HI83414 Free and Total Chlorine Specifications Range 0.00 to 5.00 mg/L (ppm) Resolution 0.01 mg/L (ppm) from 0.00 to 3.50 mg/L (ppm) ; 0.10 above 3.50 mg/L (ppm) Accuracy @25°C/77°F ±0.02 mg/L @ 1.00 mg/L Detector silicon photocell with 525 nm narrow band interference filters Method adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G. Standards 1.00 mg/L (ppm) free chlorine; 1.00 mg/L (ppm) total chlorine Calibration one-point calibration HI83414 General Specifications Light Source/ Life tungsten filament lamp / greater than 100,000 readings Display 40 x 70 mm graphic LCD (64 x 128 pixels) with backlight Log Memory 200 records Connectivity USB Environment 0 to 50°C (32 to 122°F); max 95% RH non-condensing Power Supply 230/115 Vac; 50/60 Hz; Dimensions 230 x 200 x 145 mm (9.0 x 7.9 x 5.7”) Weight 2.5 kg (88 oz.) Ordering Information HI83414-01 (115V) and HI83414-02 (230V) are supplied with sample cuvettes and caps (5), calibration cuvettes for turbidity (HI88703-11) and colorimeter (HI93414-11), silicone oil (HI98703-58), cuvette wiping cloth, scissors, power cord, instrument quality certificate, and instruction manual. CAL Check™ standards with certi›cate The HI93414-11 free and total chlorine and HI88703-11 turbidity CAL Check standards are used for calibration and performance veri›cation of the HI83414. • Supplied with Certificate of Analysis · Lot number · Expiration date · Standard value @ 25°C · Reference meter NIST traceable • Provided storage containers · Light tight · Protects from accidental breakage See page 12.24 for standards and accessories 12 Turbidity EPA meters 12.9 www.hannainst.com |

RkJQdWJsaXNoZXIy MTI3NTM=